Fire detection and alarm systems
Fire detection and alarm systems are often taken for granted and yet when they are needed in an emergency their effectiveness is a matter of life and death.
CCSS are fully aware of the importance of having a fully functional fire detection and alarm system whether your premises is small, medium, large. CCSS has the expertise to service, maintain, monitor and install addressable and conventional or even wireless fire protection systems.
Getting the best fire protection is essential because fire can result in significant losses. For this reason it is now compulsory for every business to carry out a Fire Risk Assessment.
Following a Fire Risk Assessment CCSS offers a full design installation and servicing programme in accordance with British Standard 5839 Part 1 & 6 to your and your insurers bespoke requirements.
It is vitally important that your existing fire alarm and detection system, whether conventional wired, analogue addressable or wireless, is kept in good working order.
CCSS offer a range of planned/preventative and reactive maintenance programmes to suit your individual needs.
We can service virtually any make or type of fire alarm and detection system. Upon completion of the service CCSS will issue the approved certification of maintenance for your records.
C-TEC manufactures three distinct ranges of conventional fire alarm panel, all three ranges are renowned throughout the industry for their installability, reliability and price:-
- The CFP 2-8 Zone EN54-2/4 fire panel
|

|
Our award-winning CFP EN54 fire panel comes in three versions - standard, economy and LPCB approved. Supplied in an attractive flush or surface mountable plastic enclosure, all three come with 2, 4 or 8 detection circuits and feature 4 conventional sounder circuits, 2 inputs (class change and alert) and 4 outputs (fire 1, fire 2, fault and reset). A wide range of engineering functions are also available including – dependent on the model purchased – selectable zone delays, coincidence, non-latching zones and comprehensive fault diagnostics facilities. Attractively designedand extremely cost-effective, the CFP is fully compliant with EN54 parts 2 & 4, the European standard for fire alarm control and indicating equipment. Push button and keyswitch versions of the CFP are available.
|
The MFP 4-28 Zone BS5839-4 fire panel
|
Our MFP 4 to 28 Zone BS fire panel was designed to fill the gap between low cost, low specification fire panels and higher priced, higher specification equipment. Expandable from 4 to28 zones in 4 zone steps, the MFP’s balance of features (4 sounder circuits, head-out fault indication and two on-board fire relays) plus its compatibility with a wide range of expansion boards makes it one of the most sophisticated BS5839-4 compliant fire panels available. Extremely popular in the Middle East and other non-European countries, the MFP boasts a wide range of engineer functions including one man detector test, sounder walk test, sounder isolate, sounder delay, auxiliary isolate and an optional short-circuit = fire facility (pre-1980 BS, no resistors in call points).
|
|
The FP 1-14 Zone BS5839-4 fire panel
 |
Our FP 1-14 Zone BS fire panel has been protecting people and property for almost two decades. Like the MFP, it is supplied in a robust metal enclosure with a lift-off lid and heavy-duty base connections to help promote an easy first fix and straightforward maintenance. The FP’s broad compatibility with virtually all known conventional smoke and heat detector ranges – a feature common to all of C-TEC’s conventional fire panels - and its ability to interpret a short circuit in any zone(s) as a fire or fault make it particularly useful for retro-installations. Optional head out monitoring units are also available for systems requiring compliance with BS5839-1 (1988).
|
We also supply and fit Addressable Fire Alarm panels from c-tek.
See the wide of range of Fire Alarm Ancillaries Devices that go with these panels. |